Hi folks,
The web installer is amazing! Thanks for making it!
In the spirit of making it easier for a non-programmer to get started with FluidNC, I'd like to suggest the following improvements:
After tweaking my new machine to get all axis working, limit switches, etc. I activated homing, hard limits and homing would not work. After looking at the source config here is what was under homing for all axis:
homing:
cycle: 2
That's it. This is inadequate to get a machine to home. I had to manually add the following to each homing section:
positive_direction: false
mpos_mm: 0
seek_mm_per_min: 1500
feed_mm_per_min: 50
settle_ms: 250
seek_scaler: 1.1
feed_scaler: 1.1
These parameters should be in the Axis tabs in the homing section, yes? And perhaps defaults added to the config by simply toggling homing to on. Luckily I have another machine here that I could look at for reference. I'm sure I could have found this information in the wiki or another forum, but it would be amazing if you could simply toggle homing to on to make it easier to get started.
Perhaps there's a reason this isn't possible?