App Icon DICOM Modality Worklist Tester

Version License Platform .NET Framework

DICOM Modality Worklist Tester is a lightweight, standalone utility designed to simulate a Modality (SCU) for testing and verifying DICOM Modality Worklist (MWL) services on a PACS or RIS (SCP).

Built on the robust Fellow Oak DICOM (fo-dicom) library, this tool provides a reliable way to query worklists without the need for complex installation or heavy runtimes.

Table of Contents

Features

  • Zero Dependencies: Built on .NET 4.8 (included natively in Windows 10 and 11). No external runtime installation is required.
  • Flexible Deployment: Available as a portable executable or MSI installer.
  • Customizable Results: Select exactly which DICOM tags to display in the results table via the Settings menu. Your preferences are saved between sessions.
  • Connectivity Tools: Integrated network Ping and DICOM Verification (C-ECHO) to troubleshoot connection issues before querying.
  • Secure: Full support for TLS (Transport Layer Security) for testing secure DICOM connections.
  • Deep Logging: Extensive logging settings to analyze communication traffic and debug DICOM associations.
  • Open Source: Free to use, modify, and distribute under the MIT License.

Screenshots

Application Screenshot Application Settings

Supported DICOM Tags

The application handles the following DICOM tags. You can configure which of these tags are visible in the result grid via the File -> Settings menu.

Tag Name Tag ID Description
PatientName (0010,0010) Patient's Name
PatientID (0010,0020) Patient ID
PatientBirthDate (0010,0030) Patient's Birth Date
PatientSex (0010,0040) Patient's Sex
PatientAge (0010,1010) Patient's Age
PatientSize (0010,1020) Patient's Size
PatientWeight (0010,1030) Patient's Weight
MedicalAlerts (0010,2000) Medical Alerts
Allergies (0010,2110) Contrast Allergies
AccessionNumber (0008,0050) Accession Number
StudyInstanceUID (0020,000D) Study Instance UID
Modality (0008,0060) Modality
RequestingPhysician (0032,1032) Requesting Physician
RequestedProcedureDescription (0032,1060) Requested Procedure Description
RequestedProcedureCodeSequence (0032,1064) Requested Procedure Code Sequence
ExamDescription (0032,1030) Study Description / Exam Description
AdmissionID (0038,0010) Admission ID
CurrentPatientLocation (0038,0300) Current Patient Location
ScheduledStationAET (0040,0001) Scheduled Station AE Title
ScheduledDate (0040,0002) Scheduled Procedure Step Start Date
ScheduledTime (0040,0003) Scheduled Procedure Step Start Time
ScheduledPerformingPhysicianName (0040,0006) Scheduled Performing Physician's Name
ScheduledProcedureStepDescription (0040,0007) Scheduled Procedure Step Description
ScheduledProtocolCodeValue (0040,0008) > (0008,0100) Code Value
ScheduledProtocolCodeMeaning (0040,0008) > (0008,0104) Code Meaning
ScheduledProtocolCodeScheme (0040,0008) > (0008,0102) Coding Scheme Designator
ScheduledProcedureStepID (0040,0009) Scheduled Procedure Step ID
ScheduledStationName (0040,0010) Scheduled Station Name
ScheduledProcedureStepLocation (0040,0011) Scheduled Procedure Step Location
PreMedication (0040,0012) Pre-Medication
ScheduledProcedureStepStatus (0040,0020) Scheduled Procedure Step Status
RequestedProcedureID (0040,1001) Requested Procedure ID
ReasonForRequestedProcedure (0040,1002) Reason for Requested Procedure
RequestedProcedurePriority (0040,1003) Requested Procedure Priority
OrderEnteredBy (0040,2008) Order Entered By
OrderEntererLocation (0040,2009) Order Enterer Location
ImagingServiceRequestComments (0040,2400) Imaging Service Request Comments

Requirements

  • OS: Windows 10 or Windows 11.
  • Framework: .NET Framework 4.8 (Pre-installed on supported OS).

Installation

You can choose between the Windows Installer or the Portable version.

Option 1: Portable (Recommended - does not require administrative privileges)

  1. Download the ZIP file from the latest release.
  2. Extract the files to a folder of your choice.
  3. Run DMWLT4.exe.

Option 2: Installer

  1. Download the MSI Installer from the latest release.
  2. Double-click the file to install the application.
  3. Launch DICOM Modality Worklist Tester from your Start Menu.

⚠️ Microsoft SmartScreen Warning

Because this is an open-source tool and is not digitally signed with a paid certificate, you may see a "Windows protected your PC" warning (Microsoft Defender SmartScreen) when you try to run the application for the first time.

To proceed:

  1. Click More info.
  2. Click Run anyway.

This is a standard warning for unsigned software and does not indicate a security threat.

Usage

  1. Configure Connection: Enter the IP, Port, and AE Title of the target Worklist SCP (RIS/PACS).
  2. Set Local AE: Configure your local Calling AE Title.
  3. Test Connection: Use the Ping or DICOM Echo buttons to verify network visibility.
  4. Query: Enter search criteria (e.g., Modality, Date, or Patient Name) and execute the query.
  5. Review: Check the results list. You can customize visible columns via File -> Settings.

Reporting Bugs & Feature Requests

If you encounter any bugs or have an idea for a new feature, please open an issue in the Issues section of this repository.

  • Bugs: Please provide steps to reproduce the issue and attach relevant logs if possible.
  • Features: Describe the desired functionality and how it would improve the tool.

📄 License

This project is licensed under the MIT License - see the LICENSE file for details.

🙏 Acknowledgments


Disclaimer: This software is intended for testing and simulation purposes only. It is not certified for clinical use or primary diagnosis.