117 changes: 117 additions & 0 deletions syllabuses/Workshop/TIG Welder/risk-assessment.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,117 @@
# TIG Welder

## Fire

### Severity

H

### Likelihood

L

### Who may be harmed & how

The space, and any users in it

### Control measures

- Users must clear the area of flammable materials before any welding takes place
- Metal welding table installed, walls/conduits shielded
- Fire extinguisher installed in the welding area

## Fumes

### Severity

M

### Likelihood

M

### Who may be harmed & how

Users, and other people in the room may breathe harmful fumes from the welding process.

### Control measures

- Users trained to prep and clean their workpieces, reducing fumes.
- Large extractor fan installed beside the welding area and is capable of cycling the room air once every 70 seconds

## Gas bottle falling over

### Severity

M

### Likelihood

L

### Who may be harmed & how

Any person nearby. If the valve were damaged, cylinder could become a projectile.

### Control measures

- Only cylinders that have been inspected for safety and come from a reputable supplier can be used.
- Gas bottle should be chained to wall, out of the way

## Burns from hot objects

### Severity

M

### Likelihood

M

### Who may be harmed & how

User, and possibly others nearby, may suffer burns from handling hot objects.

### Control measures

- Users trained to use appropriate tools and PPE, and to leave the area safe for other users
- Signage installed to remind others there may be hot objects left there

## Oxygen depletion from compressed gas release

### Severity

H

### Likelihood

L

### Who may be harmed & how

Any person in the room may suffer from asphyxiation.

### Control measures

- Amount of gas in the room is limited to ensure oxygen levels remain safe, even after accidental release.
- Ventilation installed
- Appropriately sized gas cylinders to be used - see wiki.ehlab.uk/tigwelder:oxygen

## UV Radiation Exposure

### Severity

M

### Likelihood

L

### Who may be harmed & how

User and other persons nearby may suffer eye/skin damage.

### Control measures

- Users trained to use appropriate PPE
- Welding curtain installed, users trained to use it.