Skip to content

Home Assistant integration for Siemens LOGO!-driven shutters. Uses your existing switch/sensor entities for timed position control, per-direction stop sequences, shade presets, motion-sensor tracking, and optional end-stop overrun—one config entry per cover.

Notifications You must be signed in to change notification settings

loreweaver-solutions/logo-shutters

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

10 Commits
 
 
 
 
 
 
 
 
 
 

Repository files navigation

LOGO Shutters (Home Assistant)

Custom cover platform for Siemens LOGO! based shutter/covers driven by self-holding relays. Each config entry represents one cover and uses existing Home Assistant entities (e.g., Modbus switches/binary_sensors) for control and feedback.

Features

  • Per-cover config (add one integration entry per cover)
  • Use existing switch entities for up and down
  • Optional binary sensors for moving up/down feedback; when provided, manual/physical moves are tracked as motion starts/stops
  • Time-based position tracking with configurable open/close durations
  • Optional initial position restore value
  • Optional overrun time at fully open/closed for motor settle
  • Configurable stop sequences (separate for up/down; optional common fallback)
  • Configurable shade position + entity service logo_shutters.set_shade
  • Fully HACS compatible

Install (HACS)

  1. Add this repository as a custom repository in HACS (category: integration).
  2. Install LOGO Shutters.
  3. Restart Home Assistant.
  4. Add the integration via Settings → Devices & Services → Add Integration → LOGO Shutters.

Stop sequence format

Provide a YAML/JSON list where each step defines a service, optional entity_id, optional service_data, and optional delay between steps. You can set:

  • stop_sequence_up: used when stopping an up/open movement
  • stop_sequence_down: used when stopping a down/close movement
  • stop_sequence: optional fallback if direction is unknown

Example:

- service: switch.turn_off
  entity_id: switch.logo_up
- service: switch.turn_off
  entity_id: switch.logo_down
- service: switch.turn_on
  entity_id: switch.logo_stop
  delay: 0.2

If no stop sequence is provided, both direction switches are turned off.

Shade service

  • Configure shade_position (0-100) per cover in options.
  • Call service logo_shutters.set_shade with entity_id of the cover to move it to that percentage.

Notes

  • Position is estimated from timing; add limit sensors if you need exact positioning.
  • On restart, the cover restores the last known position if available; otherwise it uses the configured initial position.